|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
N PA on Pending 20x5x12.8 Features Small size, light weight. Low coil power consumption 0.12W. PC board mounting, SIL terminal Suitable for household electrical appliance, automation system, electronic equipment, instrument, meter, telecommunication facilities and remote control facilities. Ordering Information NPA A S 5 DC12V 1 23 4 5 1 Part numberNPA NPA2 2 Contact arrangement A:1A 3 Enclosure: S: Sealed NIL: Dust cover 4 Contact current3:3A5:5A 5 Coil rated Voltage(V)DC:3,4.5,5,6,12,18,24 Contact Data Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance & Voltage drop Operation Electrical life Mechanical 1A SPSTNO Silver Alloy Gold clad 3A,5A/30VDC,250VAC ; 150W 1250VAC 110VDC 250VAC 30m ( at 1A/6V) 1y105 2y107 min Load:0.1mA/0.1VDC reference value Max. Switching Current:5A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 CAUTION: Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not recommended for subsequent use in low level applications. Coil Parameter Coil voltage VDC Rated current mA Pickup voltage VDC(max) (70%of rated voltage ) 3.5 4.2 6.3 8.4 12.6 16.8 release voltage VDC(min) (5% of rated voltage) 0.25 0.3 0.45 0.6 0.9 1.2 0.18 6 3 0.12 6 3 Coil power Consumption W Operate Time ms Release Time ms Dash numbers Coil resistance 10% 208 300 675 1200 2700 3200 Rated NPA-005 NPA-006 NPA-009 NPA-012 NPA-018 NPA-024 5 6 9 12 18 24 Max. 6 7.2 10.8 14.4 21.6 28.8 24 20 13.3 10 6.7 5 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 39 www.dblectro.com NPA Operation condition Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 1000M min (at 500VDC) Item 7 of IEC255-5 Item 6 of IEC255-5 Item 6 and 8 of IEC255-5 IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca 50Hz 1000V 50Hz 2000V Surge voltage:4kV Functional 147m/s2 11ms Survival 980m/s2 6ms 10~55Hz Functional double amplitude 2.5mm Survival double amplitude 3.5mm 5N 235x2 3x0.5s -40~70 5%~85% (at 40) 3g of IEC255-19-1 and minimum sample size 24. Qualification inspection: Perform the qualification test as specified in the table Dimensions (Unit: mm) NPA NPA2 Mounting (Bottom views) Dimensions mm 0.25 0.3 0.5 0.8 1.1 1.2 1.3 2.54 3.5 5.0 5.08 10.16 12.5 20 inch 0.010 0.012 0.020 0.031 0.046 0.047 0.051 0.100 0.138 0.197 0.200 0.300 0.504 0.787 Wiring diagram (Bottom views) NOTES 1).Dimensions are in millimeter. 2).Inch equivalents are given for general information only. www.dblectro.com |
Price & Availability of NPA |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |